INVARIANT MEASUREMENT OF THE PARAMETERS OF AN ACTIVE-INDUCTIVE BIPOLAR BY THE PHASE METHOD
Keywords:
two-pole, measurement, phase method, conversion sensitivityAbstract
The measuring circuit (MC) of a microcontroller meter designed for invariant measurement of the parameters of an active-inductive bipolar is investigated. A method for calculating the parameters of the MC elements and analyzing the sensitivity of converting the measured parameters into a phase signal is described.